-40%

Dental Medical 18L Autoclave Sterilizer Vacuum Steam Sterilization Automatically

$ 369.6

Availability: 99 in stock
  • Inside capacity: 18 Liter
  • Country/Region of Manufacture: China
  • Condition: New
  • Sterilizer temperature/pressure: 121℃/0.12Mpa; 134℃/0.22Mpa
  • Sterilizer Type: Autoclave (Steam Sterilizer)
  • Brand: AZDENT
  • Chamber capacity: Ø25×D35CM (Ø9.84×D13.78inch)
  • UPC: 703430258262
  • Model: TR250NM-1
  • Sterilize time: 25Min/6Min
  • Intended Use/Discipline: Dental Laboratory, Dentistry
  • Power: 1000W AC110V/8A AC220V/4A
  • Material: Stainless steel #304
  • MPN: MJQ1020100923

    Description

    Dental Autoclave Steam Sterilizer Medical sterilization 18 L
    Description:
    Chamber capacity:Ø25×D35CM (Ø9.84×D13.78inch)
    Inside capacity:18 Liter
    Material:Stainless steel #304
    Outside Size(L*W*H) :58*39*36 CM
    Packing Size(L*W*H) :64*44*36.5CM
    Sterilizer temperature/pressure:121℃/0.12Mpa; 134℃/0.22Mpa
    Sterilize time:25Min/6Min
    Power:1000W
    AC110V/8A
    AC220V/4A
    SAFETY : Heating-over protection ; safety valve
    Safety equipment:
    1.Pressure adjustment: adjust the inter pressure, if over standard value
    automatic vent
    2.    Avoid overheat protect device: when inter temperature overheat, power break electric current automatically.
    Temp and Press display :Led several windows
    Disinfection principle:Uses the vapor power emissions cold air / 2 times
    Caution:
    1.Before each use, distilled water is better .
    2.Do not use any corrosive or chemical water as the disinfection.
    3.Do not share the same electricoutllet with other electrical apparetus.
    4.Please pay attention to correct voltage and frequency.
    5.Connect steam exhaust pipe with the steam vent,before operation.
    Packing:
    main unit 1pc
    Standard accessories:
    Tray Rack 1pc
    Tray 3pcs(size:26*15*2cm)
    Tray removal tong 1pc
    Draining Tube 1pc
    Intake pipe 1pc
    Operation manual 1pc
    Power cord  1pc
    K181993
    Device Classification Name
    Sterilizer, Steam
    510(K) Number
    K181993
    Device Name
    STURDY Autoclave Super Microm (Models SA-260MA And SA-260MA-R)
    Regulation Number
    880.6880
    Classification Product Code
    FLE
    Date Received
    7/26/2018
    Decision Date
    11/1/2019
    Device Class
    2
    Regulation Number
    21CFR880.6880
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid it on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    The item has been cleaned and handled in accordance with the manufacturer’s instructions
    Seller's name: baitsramed
    City: Shenzhen State: Gunagdong ,China
    Telephone number: 0755-88668399